Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy

  • Yoshihiro Haga
    Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan
  • Koichi Chida
    Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan
  • Yuichiro Kimura
    Department of Respiratory Medicine, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan
  • Shinsuke Yamanda
    Department of Respiratory Medicine, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan
  • Masahiro Sota
    Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan
  • Mitsuya Abe
    Department of Radiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan
  • Yuji Kaga
    Department of Radiology, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan
  • Taiichiro Meguro
    Department of Cardiovascular Medicine, Sendai Kousei Hospital, Sendai, Miyagi, Japan, Hirosemachi 4-15, Aobaku, Sendai 980-0873, Japan
  • Masayuki Zuguchi
    Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan

Search this article

Abstract

<jats:title>Abstract</jats:title><jats:p>Although the clinical value of fluoroscopically guided respiratory endoscopy (bronchoscopy) is clear, there have been very few studies on the radiation dose received by staff during fluoroscopically guided bronchoscopy. The International Commission on Radiological Protection (ICRP) is suggesting reducing the occupational lens dose limit markedly from 150 to 20 mSv/year, averaged over defined periods of five years. The purpose of this study was to clarify the current occupational eye dose of bronchoscopy staff conducting fluoroscopically guided procedures. We measured the occupational eye doses (3-mm-dose equivalent, Hp(3)) of bronchoscopy staff (physicians and nurses) over a 6-month period. The eye doses of eight physicians and three nurses were recorded using a direct eye dosimeter, the DOSIRIS. We also estimated eye doses using personal dosimeters worn at the neck. The mean ± SD radiation eye doses (DOSIRIS) to physicians and nurses were 7.68 ± 5.27 and 2.41 ± 1.94 mSv/6 months, respectively. The new lens dose limit, 20 mSv/year, may be exceeded among bronchoscopy staff, especially physicians. The eye dose of bronchoscopy staff (both physicians and nurses) was underestimated when measured using a neck dosimeter. Hence, the occupational eye dose of bronchoscopy staff should be monitored. To reduce the occupational eye dose, we recommend that staff performing fluoroscopically guided bronchoscopy wear Pb glasses. correct evaluation of the lens dose [Hp(3)] using an eye dosimeter such as the DOSIRIS is necessary for bronchoscopy staff.</jats:p>