- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
In-vitro spectrometric analysis of hyperlactatemia and lactic acidosis in buffer relating to sepsis
-
- Nystha Baishya
- Research Center for Biomedical Engineering, City, University of London, London, UK
-
- Mohammad Mamouei
- Research Center for Biomedical Engineering, City, University of London, London, UK
-
- Karthik Budidha
- Research Center for Biomedical Engineering, City, University of London, London, UK
-
- Meha Qassem
- Research Center for Biomedical Engineering, City, University of London, London, UK
-
- Pankaj Vadgama
- School of Engineering and Materials Science, Queen Mary University of London, London, UK
-
- Panicos Kyriacou
- Research Center for Biomedical Engineering, City, University of London, London, UK
Search this article
Description
<jats:p> The normal range for pH in the human body is 7.35-7.45. When pH falls below 7.3, it is considered as severe acidemia. Acidemia, together with increased blood lactate concentrations (hyperlactatemia) constitute a severe threat to life, which is often referred to as lactic acidosis. The feasibility of near infrared transmission/reflectance spectroscopy as a tool to determine lactate concentration levels and pH, independently, has been well established. However, the effects on spectral features arising from simultaneous variations in pH and lactate are not fully understood. Hence, this paper reports on a spectroscopic study of 37 different lactate concentrations that were prepared at three different pH levels (7.4, 7.0 and 6.5). Near infrared spectra were acquired in the range 800-2500 nm, and were later divided into four spectral ranges. Further investigations were carried out on various wavelengths within each spectral range and sample set. Furthermore, partial least squares regression with cross-validation was performed on all data sets. The results showed a clear interdependence and overlapping spectral behavior between blood lactate concentrations and pH. The findings from this study suggest that for an accurate estimation of blood lactate using this technique, the pH of the sample must be previously known. </jats:p>
Journal
-
- Journal of Near Infrared Spectroscopy
-
Journal of Near Infrared Spectroscopy 29 (1), 53-59, 2020-11-16
SAGE Publications
- Tweet
Details 詳細情報について
-
- CRID
- 1360294647357076096
-
- ISSN
- 17516552
- 09670335
-
- Data Source
-
- Crossref