The 360° circumferential opening of Schlemm's canal in normal individuals detected by enhanced depth imaging optical coherence tomography
書誌事項
- 公開日
- 2020-02
- 権利情報
-
- http://creativecommons.org/licenses/by-nc/4.0
- DOI
-
- 10.1097/md.0000000000019187
- 公開者
- Ovid Technologies (Wolters Kluwer Health)
この論文をさがす
説明
<jats:sec> <jats:title>Abstract</jats:title> <jats:p>We aimed to observe the opening status and morphological parameters of Schlemm's canal (SC) in normal eyes using enhanced depth imaging optical coherence tomography (EDI-OCT).</jats:p> <jats:p>Consecutive EDI-OCT scans were used to examine the right eye of 20 normal individuals. EDI-OCT was performed clockwise for 8 regions (at the 12:00, 1:30, 3:00, 4:30, 6:00, 7:30, 9:00 and 10:30 o’clock positions). Image processing and analysis in java software was used to measure the area, perimeter, and diameter of SC. Twenty-one serial scans of each region were evaluated and a total of 168 images were included in the analyses of each eye.</jats:p> <jats:p>The SC was detected in 100.0% of the sections. The distribution of individual measurements of SC was highly variable. The mean values of SC size significantly differed among the different clock-face positions. The mean values of the area, perimeter, and diameter of SC in the 9:00 o’clock position were the lowest, and those at the 7:30 o’clock position were the highest (<jats:italic toggle="yes">P</jats:italic> < .05). There was no obvious association between intraocular pressure and SC size at any clock position.</jats:p> <jats:p>Although SC tends to open circumferentially in normal individuals, the distribution of individual measurements is highly variable. Morphological manifestation of SC measured by EDI-OCT is a useful way to evaluate the circumferential opening status of SC.</jats:p> </jats:sec>
収録刊行物
-
- Medicine
-
Medicine 99 (7), e19187-, 2020-02
Ovid Technologies (Wolters Kluwer Health)