- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes
-
- Eman Y. Z. Frag
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
-
- Gehad G. Mohamed
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
-
- Mohamed M. Khalil
- Chemistry Department, Faculty of Science, Beni Suef University, Beni Suef, Egypt
-
- Mohammad M. A. Hwehy
- Chemistry Department, Faculty of Science, Beni Suef University, Beni Suef, Egypt
Search this article
Description
<jats:p>This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10<jats:sup>−7</jats:sup>to 10<jats:sup>−2</jats:sup> mol L<jats:sup>−1</jats:sup>. The electrodes show Nernstian slope value of and mV decade<jats:sup>−1</jats:sup>for CPE and PVC membrane electrodes at 30<jats:sup>∘</jats:sup>C, respectively. The potential is nearly stable over the pH range 3.0–6.0 and 2.0–7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets), and biological fluid (urine). The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of and with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method.</jats:p>
Journal
-
- International Journal of Analytical Chemistry
-
International Journal of Analytical Chemistry 2011 1-7, 2011
Hindawi Limited
- Tweet
Details 詳細情報について
-
- CRID
- 1360298344181779968
-
- ISSN
- 16878779
- 16878760
-
- Data Source
-
- Crossref