Relationships Between Types of Protective Eyewear and Eye Lens Dose Within Endoscopic Retrograde Cholangiopancreatography
-
- Erika Nakajima
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences , 300-0394, 4669-2 Ami Amimachi Inashiki County, Ibaraki Prefecture , Japan
-
- Hitoshi Sato
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences , 300-0394, 4669-2 Ami Amimachi Inashiki County, Ibaraki Prefecture , Japan
抄録
<jats:title>Abstract</jats:title> <jats:p>In this study, variations in eye lens dose across different types of protective operator eyewear as well as the most appropriate protective methods when conducting endoscopic retrograde cholangiopancreatography were evaluated. The eye lens doses of 10 types of commercially available protective eyewear were compared. The ratio of the measured value near the eye to the measured value at the eye lens position ranged from 0.65 to 5.40 and it varied according to the mounting position of the dosemeter as well as the type of protective eyewear. Thus, the eye lens dose may have been overestimated or underestimated. Regardless of the working conditions, a face shield type of protective eyewear is recommended to reduce the eye lens dose. Moreover, it is preferable to attach a lens dosemeter near the eye to measure and evaluate the eye lens dose.</jats:p>
収録刊行物
-
- Radiation Protection Dosimetry
-
Radiation Protection Dosimetry 198 1399-, 2022-09-04
Oxford University Press (OUP)
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1360298754829282304
-
- ISSN
- 17423406
- 01448420
-
- データソース種別
-
- Crossref
- KAKEN