Lens Equivalent dose of Staff During Endoscopic Retrograde Cholangiopancreatography: Dose Comparison Using Two Types of Dosemeters

  • Yoshiaki Morishima
    Department of Radiological Technology, Tohoku Medical and Pharmaceutical University Hospital , 1-12-1 Fukumuro, Miyagino-ku, Sendai 983-8512 , Japan
  • Koichi Chida
    Department of Radiological Technology, Tohoku University School of Health Sciences , Sendai 980-8575 , Japan
  • Takayoshi Meguro
    Gastroenterology Center, Tohoku Medical and Pharmaceutical University Hospital , Sendai 983-8512 , Japan
  • Morihisa Hirota
    Gastroenterology Center, Tohoku Medical and Pharmaceutical University Hospital , Sendai 983-8512 , Japan
  • Hiroo Chiba
    Department of Radiological Technology, Tohoku Medical and Pharmaceutical University Hospital , 1-12-1 Fukumuro, Miyagino-ku, Sendai 983-8512 , Japan
  • Hiroshi Fukuda
    Department of Radiology Faculty of Medicine, Tohoku Medical and Pharmaceutical University , Sendai 983-8356 , Japan

抄録

<jats:title>Abstract</jats:title> <jats:p>This study aimed to compare the lens equivalent dose (LED) measured during endoscopic retrograde cholangiopancreatography (ERCP) using DOSIRIS™ as a dedicated dosemeter to that measured using glass badges to determine if glass badges can be alternative tools for LED measurement.</jats:p> <jats:p>LEDs for physicians during ERCP were measured using the DOSIRIS™ [3-mm dose equivalent] worn on the outer edge of the eyes and personal dosemeters (glass badges) [0.07-mm dose equivalent] worn on the right and left sides of the neck.</jats:p> <jats:p>The cumulated doses over 6 months for the left eye using DOSIRIS™ were 9.5 and 11.8 mSv for physicians A and B, whereas doses measured using glass badges were 7.5 and 11.6 mSv, respectively. The LEDs of the physicians at the left eye and left neck side showed almost similar values and were significantly correlated (r = 0.95; p &lt; 0.01).</jats:p> <jats:p>For an accurate LED measurement during ERCP, using a dosemeter such as DOSIRIS™ is recommended, although similar LED estimation values were reported using glass badges on the left neck side.</jats:p>