Transcatheter closure of perimembranous ventricular septal defect using amplatzer ductal occluder
-
- Sang Mi Lee
- Severance Hospital Yonsei University College of Medicine Seoul Republic of Korea
-
- Jin Young Song
- Sejong General Hospital Bucheon Republic of Korea
-
- Jae Young Choi
- Severance Hospital Yonsei University College of Medicine Seoul Republic of Korea
-
- Sang Yoon Lee
- Sejong General Hospital Bucheon Republic of Korea
-
- Jae Sook Paik
- Sejong General Hospital Bucheon Republic of Korea
-
- So Ick Chang
- Sejong General Hospital Bucheon Republic of Korea
-
- Woo Seop Shim
- Sejong General Hospital Bucheon Republic of Korea
-
- Seong Ho Kim
- Sejong General Hospital Bucheon Republic of Korea
説明
<jats:sec><jats:title>Objective</jats:title><jats:p>To show that transcatheter closure of perimembranous ventricular septal defect (PMVSD) with the Amplatzer ductal occluder (ADO, AGA Medical Corp, Plymouth, Minnesota) is a safe and effective treatment option.</jats:p></jats:sec><jats:sec><jats:title>Background</jats:title><jats:p>Transcatheter closure of PMVSD is a challenging procedure. Recently, the Amplatzer PMVSD occluder (APMVSDO, AGA Medical Corp, Plymouth, Minnesota) has been shown to be effective in closing hemodynamically significant PMVSDs. However, the high incidence of complete atrioventricular block (CAVB) after device occlusion of a PMVSD has been a hot issue as well.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Among several devices used in closing PMVSD percutaneously, we prefer the ADO because of the anatomic resemblance between PMVSD with aneurysm and patent ductus arteriosus, and it has no right ventricular disc which may contribute to the occurrence of CAVB.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Between August 2009 and May 2012, 21 patients (5 males and 16 females) underwent percutaneous PMVSD closure using ADO. The patients' ages ranged from 3 to 42 years (median: 7 years), and their weights ranged from 18 kg to 60 kg (median: 27 kg). All patients showed echocardiographic signs of left ventricular volume overload and trivial to small mitral regurgitation (Qp/Qs = 1.7 ± 0.4). The mean defect size of the right ventricular side was 4.3 ± 1.0 mm. Devices 2 mm larger than the measured narrowest VSD diameter were selected in most patients. The ADOs were successfully implanted in all patients without any significant complications except one transient CAVB, one case of delivery wire fracture, and one case of surgery due to significant residual leak. Small residual shunts were observed immediately after the device implantation, but they disappeared during follow‐up for 18 of 20 patients. The mean follow‐up period was 20 ± 9 months, and CAVB or aortic regurgitation was not observed in all patients.</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>Transcatheter closure of PMVSD with the ADO is a safe and promising treatment option, but long‐term follow‐up in a large number of patients would be warranted. © 2013 Wiley Periodicals, Inc.</jats:p></jats:sec>
収録刊行物
-
- Catheterization and Cardiovascular Interventions
-
Catheterization and Cardiovascular Interventions 82 (7), 1141-1146, 2013-08-20
Wiley