- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Thickness measurement of nm HfO<sub>2</sub> films
Search this article
Description
<jats:title>Main text</jats:title> <jats:p>A pilot study for the thickness measurement of HfO<jats:sub>2</jats:sub> films was performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this pilot study was to ensure the equivalency in the measurement capability of national metrology institutes for the thickness measurement of HfO<jats:sub>2</jats:sub> films. In this pilot study, the thicknesses of six HfO<jats:sub>2</jats:sub> films with nominal thickness from 1 nm to 4 nm were measured by X-ray Photoelectron Spectroscopy (XPS), X-ray Reflectometry(XRR), X-ray Fluorescence Analysis (XRF), Transmission Electron Spectroscopy (TEM), Spectroscopic Ellipsometry (SE) and Rutherford Backscattering Spectrometry (RBS). The reference thicknesses were determined by mutual calibration of a zero-offset method (Medium Energy Ion Scattering Spectroscopy (MEIS) of KRISS) and a method traceable to the length unit (the average thicknesses of three XRR data except the thinnest film). These reference thicknesses are traceable to the length unit because they are based on the traceability of XRR. For the thickness measurement by XPS, the effective attenuation length of Hf 4f electrons was determined. In the cases of XRR and TEM, the offset values were determined from a linear fitting between the reference thicknesses and the individual data by XRR and TEM. The amount of substance of HfO<jats:sub>2</jats:sub>, expressed as thickness of HfO<jats:sub>2</jats:sub> films (in both linear and areal density units), was found to be a good subject for a CCQM key comparison.</jats:p> <jats:p>To reach the main text of this paper, click on <jats:ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://www.bipm.org/documents/20126/46087117/CCQM-P190.pdf/5eaf9732-659b-fc91-c1b9-7d14f25112d1" xlink:type="simple">Final Report</jats:ext-link>. </jats:p> <jats:p>The final report has been peer-reviewed and approved for publication by the CCQM.</jats:p>
Journal
-
- Metrologia
-
Metrologia 58 (1A), 08016-, 2021-01-01
IOP Publishing
- Tweet
Details 詳細情報について
-
- CRID
- 1360579818088714880
-
- ISSN
- 16817575
- 00261394
-
- Data Source
-
- Crossref