-
- Petr Widimsky
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Zbynek Straka
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Petr Stros
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Karel Jirasek
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Jaroslav Dvorak
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Jan Votava
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Libor Lisa
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Tomas Budesinsky
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Miroslav Kolesar
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Tomas Vanek
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
-
- Petr Brucek
- From Cardiocenter, 3rd Medical School, Charles University, Hospital Kralovske Vinohrady, Prague, Czech Republic.
書誌事項
- タイトル別名
-
- A Randomized Comparison Between Off-Pump and On-Pump Surgery Angiographic Results of the PRAGUE-4 Trial
説明
<jats:p> <jats:bold> <jats:italic>Background—</jats:italic> </jats:bold> Off-pump coronary bypass surgery has become a widely used technique during recent years. However, limited data are available with regard to 1-year patency of bypass grafts implanted on the beating heart in unselected consecutive bypass surgery candidates. The aim of this study was to compare 1-year angiographic patency of bypass grafts done on the beating heart (off pump) with those done classically (on pump). </jats:p> <jats:p> <jats:bold> <jats:italic>Methods and Results—</jats:italic> </jats:bold> The PRAGUE-4 trial randomized 400 consecutive nonselected cardiac surgery candidates into group A (on pump; n=192) and group B (off pump; n=208). One-year follow-up coronary angiography was done in 255 patients. The arterial graft patency after 1 year was 91% in both groups. Saphenous graft patency was 59% (on pump) versus 49% (off pump; <jats:italic>P</jats:italic> =NS). Saphenous graft patency per patient was lower in the off-pump group: 0.7 patent anastomosis per patient versus 1.1 patent anastomosis in the on-pump group ( <jats:italic>P</jats:italic> <0.01). There were 46% on-pump patients with all grafts patent versus 52% off-pump patients ( <jats:italic>P</jats:italic> =NS). Grafts anastomosed distally to collateralized chronic total occlusions of native coronary arteries remained patent in 100% on the left anterior descending artery compared with 23% on other arteries ( <jats:italic>P</jats:italic> <0.0001). </jats:p> <jats:p> <jats:bold> <jats:italic>Conclusions—</jats:italic> </jats:bold> The patency of arterial coronary bypass grafts done on the beating heart is excellent and equal to grafts done on pump. The off-pump procedure in the unselected patient population results in fewer patent saphenous grafts per patient. </jats:p>
収録刊行物
-
- Circulation
-
Circulation 110 (22), 3418-3423, 2004-11-30
Ovid Technologies (Wolters Kluwer Health)