Human Immunoglobulin Adsorption Investigated by Means of Quartz Crystal Microbalance Dissipation, Atomic Force Microscopy, Surface Acoustic Wave, and Surface Plasmon Resonance Techniques

  • Cheng Zhou
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Jean-Michel Friedt
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Angelina Angelova
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Kang-Hoon Choi
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Wim Laureyn
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Filip Frederix
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Laurent A. Francis
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Andrew Campitelli
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Yves Engelborghs
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium
  • Gustaaf Borghs
    Biosensors group, Interuniversity Microelectronics Center (IMEC), Kapeldreef 75, 3001 Leuven, Belgium, Laboratory of Biomolecular Dynamic, Department of Chemistry KULeuven, Celestijnenlaan 200D, 3001 Leuven, Belgium, PCPM, Université catholique de Louvain, Croix du Sud 1, 1348 Louvain-la-Neuve, Belgium

Journal

  • Langmuir

    Langmuir 20 (14), 5870-5878, 2004-06-08

    American Chemical Society (ACS)

Citations (4)*help

See more

Details 詳細情報について

Report a problem

Back to top