Macular Choroidal Thickness and Volume in Healthy Pediatric Individuals Measured by Swept-Source Optical Coherence Tomography

  • Toshihiko Nagasawa
    Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan 2Department of Ophthalmology and Visual Sciences, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
  • Yoshinori Mitamura
    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
  • Takashi Katome
    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
  • Kayo Shinomiya
    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
  • Takeshi Naito
    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan
  • Daisuke Nagasato
    Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan
  • Yukiko Shimizu
    Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan
  • Hitoshi Tabuchi
    Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji, Japan
  • Yoshiaki Kiuchi
    Department of Ophthalmology and Visual Sciences, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan

この論文をさがす

説明

We evaluated the choroidal thickness and volume in healthy pediatric individuals by swept-source optical coherence tomography (SS-OCT) and compared the findings to those of adults.We examined 100 eyes of 100 healthy pediatric volunteers (3-15 years) and 83 eyes of 83 healthy adult volunteers (24-87 years) by SS-OCT with a tunable long wavelength laser source. The three-dimensional raster scan protocol was used to construct a choroidal thickness map. When the built-in software delineated an erroneous chorioscleral border in the B-scan images, manual segmentation was used.The central choroidal thickness and volume within a 1.0-mm circle were significantly larger in the children (260.4 ± 57.2 μm, 0.205 ± 0.045 mm(3)) than in the adults (206.1 ± 72.5 μm, 0.160 ± 0.056 mm(3), both P0.0001). In the children, the mean choroidal thickness of the nasal area was significantly thinner than that of all other areas (P0.005). Pediatric choroidal thinning with increasing age in the central area was faster than that in the outer areas. Stepwise regression analysis showed that the axial length and body mass index had the highest correlation with the choroidal thickness (R(2) = 0.313, P0.0001).The macular choroidal thickness and volume in the pediatric individuals were significantly larger than those in the adults. The pediatric choroidal thinning with increasing age is more rapid in the central area. Pediatric choroidal thickness is associated with several systemic or ocular parameters, especially the axial length and body mass index. These differences should be remembered when the choroidal thickness is evaluated in pediatric patients with retinochoroidal diseases.

収録刊行物

被引用文献 (2)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ