Absolute Seebeck coefficient of platinum from 80 to 340 K and the thermal and electrical conductivities of lead from 80 to 400 K

  • J. P. Moore
    Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830
  • R. S. Graves
    Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830

書誌事項

公開日
1973-03-01
DOI
  • 10.1063/1.1662324
公開者
AIP Publishing

この論文をさがす

説明

<jats:p>The absolute Seebeck coefficient of platinum was determined from 80 to 340 K by direct comparsion to lead. Results of this comparison disagree with previous results which have been used for the calculation of absolute values for other materials. The thermal conductivity λ and electrical resistivity ρ of the lead standard were also determined. The electrical resistivity could be described with a modified Gruneisen-Bloch equation which allows for the effect of thermal expansion on the Debye temperature ΘD. The ratio λρ/T was within 1% of the Sommerfeld value of 2.443×10−8 (V/K)2 from 1.0 to 5.0 ΘD.</jats:p>

収録刊行物

被引用文献 (7)*注記

もっと見る

詳細情報 詳細情報について