Absolute Seebeck coefficient of platinum from 80 to 340 K and the thermal and electrical conductivities of lead from 80 to 400 K
-
- J. P. Moore
- Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830
-
- R. S. Graves
- Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830
書誌事項
- 公開日
- 1973-03-01
- DOI
-
- 10.1063/1.1662324
- 公開者
- AIP Publishing
この論文をさがす
説明
<jats:p>The absolute Seebeck coefficient of platinum was determined from 80 to 340 K by direct comparsion to lead. Results of this comparison disagree with previous results which have been used for the calculation of absolute values for other materials. The thermal conductivity λ and electrical resistivity ρ of the lead standard were also determined. The electrical resistivity could be described with a modified Gruneisen-Bloch equation which allows for the effect of thermal expansion on the Debye temperature ΘD. The ratio λρ/T was within 1% of the Sommerfeld value of 2.443×10−8 (V/K)2 from 1.0 to 5.0 ΘD.</jats:p>
収録刊行物
-
- Journal of Applied Physics
-
Journal of Applied Physics 44 (3), 1174-1178, 1973-03-01
AIP Publishing