Mechanisms of Discordant Alternans and Induction of Reentry in Simulated Cardiac Tissue
-
- Zhilin Qu
- From the Cardiovascular Research Laboratory and the Departments of Medicine (Cardiology), Physiology, and Physiological Science, UCLA, and Cedars-Sinai Medical Center, Los Angeles, Calif.
-
- Alan Garfinkel
- From the Cardiovascular Research Laboratory and the Departments of Medicine (Cardiology), Physiology, and Physiological Science, UCLA, and Cedars-Sinai Medical Center, Los Angeles, Calif.
-
- Peng-Sheng Chen
- From the Cardiovascular Research Laboratory and the Departments of Medicine (Cardiology), Physiology, and Physiological Science, UCLA, and Cedars-Sinai Medical Center, Los Angeles, Calif.
-
- James N. Weiss
- From the Cardiovascular Research Laboratory and the Departments of Medicine (Cardiology), Physiology, and Physiological Science, UCLA, and Cedars-Sinai Medical Center, Los Angeles, Calif.
説明
<jats:p> <jats:italic>Background</jats:italic> —T-wave alternans, which is associated with the genesis of cardiac fibrillation, has recently been related to discordant action potential duration (APD) alternans. However, the cellular electrophysiological mechanisms responsible for discordant alternans are poorly understood. </jats:p> <jats:p> <jats:italic>Methods and Results</jats:italic> —We simulated a 2D sheet of cardiac tissue using phase 1 of the Luo-Rudy cardiac action potential model. A steep (slope >1) APD restitution curve promoted concordant APD alternans and T-wave alternans without QRS alternans. When pacing was from a single site, discordant APD alternans occurred only when the pacing rate was fast enough to engage conduction velocity (CV) restitution, producing both QRS and T-wave alternans. Tissue heterogeneity was not required for this effect. Discordant alternans markedly increases dispersion of refractoriness and increases the ability of a premature stimulus to cause localized wavebreak and induce reentry. In the absence of steep APD restitution and of CV restitution, sustained discordant alternans did not occur, but reentry could be induced if there was marked electrophysiological heterogeneity. Both discordant APD alternans and preexisting APD heterogeneity facilitate reentry by causing the waveback to propagate slowly. </jats:p> <jats:p> <jats:italic>Conclusion</jats:italic> —Discordant alternans arises dynamically from APD and CV restitution properties and markedly increases dispersion of refractoriness. Preexisting and dynamically induced (via restitution) dispersion of refractoriness independently increase vulnerability to reentrant arrhythmias. Reduction of dynamically induced dispersion by appropriate alteration of electrical restitution has promise as an antiarrhythmic strategy. </jats:p>
収録刊行物
-
- Circulation
-
Circulation 102 (14), 1664-1670, 2000-10-03
Ovid Technologies (Wolters Kluwer Health)
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1361981470865600896
-
- ISSN
- 15244539
- 00097322
- http://id.crossref.org/issn/00097322
-
- データソース種別
-
- Crossref