Detection of Intracranial Aneurysms with Two-dimensional and Three-dimensional Multislice Helical Computed Tomographic Angiography
-
- Marko Kangasniemi
- Department of Radiology, Helsinki University Central Hospital, Helsinki, Finland
-
- Teppo Mäkelä
- Department of Radiology, Helsinki University Central Hospital, Helsinki, Finland
-
- Seppo Koskinen
- Department of Radiology, Helsinki University Central Hospital, Helsinki, Finland
-
- Matti Porras
- Department of Radiology, Helsinki University Central Hospital, Helsinki, Finland
-
- Kristiina Poussa
- Department of Radiology, Helsinki University Central Hospital, Helsinki, Finland
-
- Juha Hernesniemi
- Department of Neurosurgery, Helsinki University Central Hospital, Helsinki, Finland
書誌事項
- 公開日
- 2004-02-01
- DOI
-
- 10.1227/01.neu.0000103448.07132.e1
- 公開者
- Ovid Technologies (Wolters Kluwer Health)
この論文をさがす
説明
<jats:title>Abstract</jats:title> <jats:sec> <jats:title>OBJECTIVE</jats:title> <jats:p>Computed tomographic angiography (CTA) has become a diagnostic method for the detection of intracranial aneurysms in cases of subarachnoid bleeding. We sought to evaluate the detection of aneurysms with CTA with a novel multislice helical computed tomographic scanner.</jats:p> </jats:sec> <jats:sec> <jats:title>METHODS</jats:title> <jats:p>Prospectively, 179 patients underwent multislice CTA, followed by digital subtraction angiography (DSA) of both carotid arteries with or without the posterior circulation, DSA of one carotid artery with or without the posterior circulation, or DSA of the posterior circulation alone. The total number of carotid arteries studied was 298, and the number of vertebrobasilar arteries studied was 124.</jats:p> </jats:sec> <jats:sec> <jats:title>RESULTS</jats:title> <jats:p>Of 178 aneurysms verified with DSA or intraoperatively, CTA failed to detect 7 aneurysms of 1 to 2 mm and 1 partially thrombosed, 4-mm aneurysm. The sensitivity and specificity of CTA for aneurysm detection were 0.96 and 0.97, respectively.</jats:p> </jats:sec> <jats:sec> <jats:title>CONCLUSION</jats:title> <jats:p>The first generation of multislice computed tomographic technology does not improve CTA to surpass DSA for the detection of small aneurysms of 1 to 2 mm. In practice, however, CTA is superior as a fast noninvasive method without complications.</jats:p> </jats:sec>
収録刊行物
-
- Neurosurgery
-
Neurosurgery 54 (2), 336-341, 2004-02-01
Ovid Technologies (Wolters Kluwer Health)
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1362262943324019712
-
- NII論文ID
- 30012789380
-
- ISSN
- 15244040
- 0148396X
- http://id.crossref.org/issn/0148396X
-
- データソース種別
-
- Crossref
- CiNii Articles