説明
We have developed a new permeance meter in the 1 MHz-1.5 GHz range using either a microstrip pickup coil or a shielded loop pickup coil. Both pickup coils and the driving plates are free from LC resonance due to impedance matching. In the MHz range we must consider signal-to-noise ratio of the pickup coil. In the GHz range we must eliminate the voltage induced by the electric field, and an electromagnetic higher order mode in the driving plates.