Direct observation of glucose fingerprint using in vivo Raman spectroscopy

  • Jeon Woong Kang
    Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Yun Sang Park
    Mobile Healthcare Laboratory, Device and System Research Center, Samsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., 130 Samsung-ro Yeongtong-gu, Suwon-si, Gyeonggi-do 16678, Republic of Korea.
  • Hojun Chang
    Mobile Healthcare Laboratory, Device and System Research Center, Samsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., 130 Samsung-ro Yeongtong-gu, Suwon-si, Gyeonggi-do 16678, Republic of Korea.
  • Woochang Lee
    Mobile Healthcare Laboratory, Device and System Research Center, Samsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., 130 Samsung-ro Yeongtong-gu, Suwon-si, Gyeonggi-do 16678, Republic of Korea.
  • Surya Pratap Singh
    Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Wonjun Choi
    Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Luis H. Galindo
    Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Ramachandra R. Dasari
    Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Sung Hyun Nam
    Mobile Healthcare Laboratory, Device and System Research Center, Samsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., 130 Samsung-ro Yeongtong-gu, Suwon-si, Gyeonggi-do 16678, Republic of Korea.
  • Jongae Park
    Mobile Healthcare Laboratory, Device and System Research Center, Samsung Advanced Institute of Technology, Samsung Electronics Co. Ltd., 130 Samsung-ro Yeongtong-gu, Suwon-si, Gyeonggi-do 16678, Republic of Korea.
  • Peter T. C. So
    Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.

説明

<jats:p>Noninvasive optical sensor can measure blood glucose levels based on the glucose Raman signal from in vivo skin.</jats:p>

収録刊行物

  • Science Advances

    Science Advances 6 (4), eaay5206-, 2020-01-24