- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
A novel octaray multielectrode catheter for high‐resolution atrial mapping: Electrogram characterization and utility for mapping ablation gaps
-
- Jakub Sroubek
- Cardiovascular Division, Department of Medicine, Deaconess Medical Center, Harvard Medical School Harvard‐Thorndike Electrophysiology Institute Boston Massachusetts
-
- Markus Rottmann
- Cardiovascular Division, Department of Medicine, Deaconess Medical Center, Harvard Medical School Harvard‐Thorndike Electrophysiology Institute Boston Massachusetts
-
- Michael Barkagan
- Cardiovascular Division, Department of Medicine, Deaconess Medical Center, Harvard Medical School Harvard‐Thorndike Electrophysiology Institute Boston Massachusetts
-
- Eran Leshem
- Cardiovascular Division, Department of Medicine, Deaconess Medical Center, Harvard Medical School Harvard‐Thorndike Electrophysiology Institute Boston Massachusetts
-
- Ayelet Shapira‐Daniels
- Cardiovascular Division, Department of Medicine, Deaconess Medical Center, Harvard Medical School Harvard‐Thorndike Electrophysiology Institute Boston Massachusetts
-
- Erez Brem
- Research and Development Biosense Webster Irwindale California
-
- Cesar Fuentes‐Ortega
- Research and Development Biosense Webster Irwindale California
-
- Jamie Malinaric
- Research and Development Biosense Webster Haifa Israel
-
- Shubhayu Basu
- Research and Development Biosense Webster Irwindale California
-
- Meir Bar‐Tal
- Research and Development Biosense Webster Haifa Israel
-
- Elad Anter
- Cardiovascular Division, Department of Medicine, Deaconess Medical Center, Harvard Medical School Harvard‐Thorndike Electrophysiology Institute Boston Massachusetts
Search this article
Description
<jats:title>Abstract</jats:title><jats:sec><jats:title>Introduction</jats:title><jats:p>Multielectrode mapping catheters improve the ability to map within the heterogeneous scar. A novel Octaray catheter with eight spines and 48 electrodes may further improve the speed and resolution of atrial mapping. The aims of this study were to (1) establish the Octaray's baseline mapping performance and electrogram (EGM) characteristics in healthy atria and to (2) determine its utility for identifying gaps in a swine model of atrial ablation lines.</jats:p></jats:sec><jats:sec><jats:title>Methods and Results</jats:title><jats:p>The right atria of eight healthy swine were mapped with Octaray and Pentaray catheters (Biosense Webster, Irvine, CA) before and after the creation of ablation lines with intentional gaps. Baseline mapping characteristics including EGM amplitude, duration, number of EGMs, and mapping time were compared. Postablation maps were created and EGM characteristics of continuous lines and gaps were correlated with pathology. Compared with Pentaray, the Octaray collected more EGMs per map (2178 ± 637 vs 1046 ± 238; <jats:italic>P</jats:italic> < 0.001) at a shorter mapping duration (3.2 ± 0.79 vs 6.9 ± 2.67 minutes; <jats:italic>P</jats:italic> < 0.001). In healthy atria, the Octaray recorded lower bipolar voltage amplitude (1.96 ± 1.83 mV vs 2.41 ± 1.92 mV; <jats:italic>P</jats:italic> < 0.001) while ablation gaps were characterized by higher voltage amplitude (1.24 ± 1.12 mV vs 1.04 ± 1.27 mV; <jats:italic>P</jats:italic> < 0.001). Ablation gaps were similarly identified by both catheters (<jats:italic>P</jats:italic> = 1.0). The frequency of “false gaps,” defined as intact ablation lines with increased voltage amplitude was more common with Pentaray (6 vs 2) and resulted from erroneous annotation of far‐field EGMs.</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>The Octaray increases the mapping speed and density compared with the Pentaray catheter. It is as sensitive for identifying ablation gaps and more specific for mapping intact ablation lines.</jats:p></jats:sec>
Journal
-
- Journal of Cardiovascular Electrophysiology
-
Journal of Cardiovascular Electrophysiology 30 (5), 749-757, 2019-02-12
Wiley
- Tweet
Details 詳細情報について
-
- CRID
- 1363107369089752960
-
- ISSN
- 15408167
- 10453873
-
- Data Source
-
- Crossref