<jats:p>This study was to determine the shear bond strengths of Ni‐Cr alloy to Ni‐Cr alloy (Group I), Ni‐Cr alloy to enamel (Group II), and Ni‐Cr alloy to dentin (Group III) using Imperva Dual, DC Metabond, All‐Bond, Geristore, and Panavla. All bonded specimens were thermocycled 2000 X (5<jats:sup>C</jats:sup>C‐55°C) after 24 hours and subjected to shear bond testing on a Universal Instron Testing Machine. In all groups of the study, Imperva Dual and CB Metabond had significantly (p < .05) higher bond values than Panavia.</jats:p>