Impact of Solvent Evaporation and Curing Protocol on Degree of Conversion of Etch-and-Rinse and Multimode Adhesives Systems
-
- Ceci Nunes Carvalho
- School of Dentistry, CEUMA University, Rua Josué Montello No 1, Renascença II, 65075120 São Luís, MA, Brazil
-
- Marcos Daniel Septímio Lanza
- Department of Restorative Dentistry, College of Dentistry, Federal University of Minas Gerais, Presidente Antonio Carlos Av 6627, Pampulha, Belo Horizonte, MG, Brazil
-
- Letícia Gomes Dourado
- School of Dentistry, CEUMA University, Rua Josué Montello No 1, Renascença II, 65075120 São Luís, MA, Brazil
-
- Edilausson Moreno Carvalho
- Discipline of Dental Materials, School of Dentistry, University Federal of Maranhão (UFMA), Av. dos Portugueses, 1966, 65085680 São Luis, MA, Brazil
-
- José Bauer
- Discipline of Dental Materials, School of Dentistry, University Federal of Maranhão (UFMA), Av. dos Portugueses, 1966, 65085680 São Luis, MA, Brazil
説明
<jats:p><jats:italic>Objectives</jats:italic>. This study evaluated the effect of air-drying time and light-curing time on the degree of conversion (DC) of three etch-and-rinse adhesive systems: ONE-STEP (OS) and ONE-STEP plus (OSP), Ambar (AMB), and two multimode adhesive systems: All-Bond Universal (ABU) and ScotchBond Universal (SBU) by Fourier transform infrared (FTIR) analysis. <jats:italic>Materials and Methods</jats:italic>. The DC of each adhesive system was analyzed with six experimental different protocols: (1) immediate light curing for 10 s without solvent volatilization; (2) 10 s solvent volatilization with air stream plus 10 s light curing; (3) 60 s solvent volatilization with air stream plus 10 s light curing; (4) immediate light curing for 20 s without solvent volatilization; (5) 10 s solvent volatilization with air stream plus 20 s light curing; and (6) 60 s solvent volatilization with air stream plus 20 s light curing. FTIR spectra were obtained, and the DC was calculated by comparing the ratio of aliphatic/aromatic double carbon bonds before and after light activation (Bluephase 20i). The DC means were analyzed by three-way analysis of variance (ANOVA) and post hoc Tukey tests (<jats:italic>α</jats:italic> = 0.05). <jats:italic>Results</jats:italic>. Three-way ANOVA showed statistically significant adhesive, air-drying, and light-cured time (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mrow><mml:mi>p</mml:mi><mml:mo><</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math>). In general, there was a trend of increased DC when the adhesives were dried and cured for longer times, but that was not observed for all the adhesives tested. The acetone-based adhesive systems require an air-drying prior to light activation. The light-curing time of 20 s increases the DC of all materials tested. <jats:italic>Conclusion</jats:italic>. The results suggested that the DC of the adhesive systems tested was material dependent. In general, the protocol with solvent evaporation for 10 seconds with air syringe plus 20 seconds of light curing finds the high values of DC.</jats:p>
収録刊行物
-
- International Journal of Dentistry
-
International Journal of Dentistry 2019 1-6, 2019-04-11
Hindawi Limited