- Integration of CiNii Books functions for fiscal year 2025 has completed
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on November 26, 2025】Regarding the recording of “Research Data” and “Evidence Data”
- Start the collection of all publicly IRDB content
- Incorporate Research Data from KAKEN
How Three Methods for Fixing a Medial Meniscal Autograft Affect Tibial Contact Mechanics
-
- Mohammad M. Alhalki
- Biomedical Engineering Graduate Group, University of California
-
- Stephen M. Howell
- Department of Mechanical Engineering, University of California at Davis, Davis, California, Clinical Investigation Facility, David Grant Medical Center, Travis Air Force Base, California
-
- Maury L. Hull
- Biomedical Engineering Graduate Group, University of California, Department of Mechanical Engineering, University of California at Davis, Davis, California
Bibliographic Information
- Published
- 1999-05
- Rights Information
-
- https://journals.sagepub.com/page/policies/text-and-data-mining-license
- DOI
-
- 10.1177/03635465990270030901
- Publisher
- SAGE Publications
Search this article
Description
<jats:p> We evaluated three methods for fixing a medial meniscal autograft to determine which method restored tibial contact mechanics closest to normal. The contact mechanics (maximum pressure, mean pressure, contact area, and location of the center of maximum pressure) of the medial tibial articular surface were determined using pressure-sensitive film while knee specimens were loaded in compression to 1000 N at 0°, 15°, 30°, and 45° of flexion. Pressure was measured for the intact knee, the knee after meniscectomy, and the knee with the original meniscus removed and reimplanted as an autograft using three different fixation methods. The contact mechanics of the autograft reinserted with bone plug fixation were closest to normal; however, the maximum pressure was significantly greater than in the intact knee. Adding peripheral sutures neither improved nor worsened the contact mechanics. Fixation with sutures only did not restore normal contact mechanics. We concluded that medial meniscal transplantation requires anatomic fixation of bone plugs attached to the anterior and posterior horns to restore contact mechanics closest to normal. Fixation of the meniscal horns with sutures alone cannot be recommended. </jats:p>
Journal
-
- The American Journal of Sports Medicine
-
The American Journal of Sports Medicine 27 (3), 320-328, 1999-05
SAGE Publications
- Tweet
Details 詳細情報について
-
- CRID
- 1363670319598549760
-
- ISSN
- 15523365
- 03635465
-
- Data Source
-
- Crossref

