Simultaneous imaging of dual‐frequency electrical conductivity using a combination of<scp>MREIT</scp>and<scp>MREPT</scp>

  • Hyung Joong Kim
    Department of Biomedical Engineering Kyung Hee University Korea
  • Woo Chul Jeong
    Department of Biomedical Engineering Kyung Hee University Korea
  • Saurav Z. K. Sajib
    Department of Biomedical Engineering Kyung Hee University Korea
  • Min‐Oh Kim
    Department of Electrical and Electronic Engineering Yonsei University Korea
  • Oh In Kwon
    Department of Mathematics Konkuk University Korea
  • Eung Je Woo
    Department of Biomedical Engineering Kyung Hee University Korea
  • Dong‐Hyun Kim
    Department of Electrical and Electronic Engineering Yonsei University Korea

書誌事項

公開日
2013-02-08
権利情報
  • http://onlinelibrary.wiley.com/termsAndConditions#vor
DOI
  • 10.1002/mrm.24642
公開者
Wiley

この論文をさがす

説明

<jats:sec><jats:title>Purpose</jats:title><jats:p>To propose a single magnetic resonance scan conductivity imaging technique providing dual‐frequency characteristics of tissue conductivity.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Using a modified spin‐echo pulse sequence, the magnetic flux density induced by externally injected currents and the<jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/mrm24642-math-0001.gif" xlink:title="urn:x-wiley:07403194:media:mrm24642:mrm24642-math-0001"/>phase map with injected current effects removed were acquired simultaneously. The low‐frequency conductivity was reconstructed from the measured magnetic flux density by the projected current density method, while the high‐frequency conductivity was reconstructed using the<jats:inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/mrm24642-math-0002.gif" xlink:title="urn:x-wiley:07403194:media:mrm24642:mrm24642-math-0002"/>maps. Three different conductivity phantoms were used to demonstrate low‐ and high‐frequency conductivity characteristics.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>A conductivity spectrum at two frequencies was successfully acquired with the proposed scheme. Magnetic resonance electrical impedance tomography is advantageous for seeing an anomaly itself wrapped with a thin insulating membrane. In addition, if the membrane is porous, the membrane property can be quantitatively visualized with magnetic resonance electrical impedance tomography. Magnetic resonance electrical properties tomography does not detect such membranes, which enable it to probe things inside an insulating membrane.</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>Considering these pros and cons and also the fact that the conductivity of biological tissue changes with frequency, a dual‐frequency conductivity imaging incorporating both magnetic resonance electrical impedance tomography and magnetic resonance electrical properties tomography in future animal and human experiments is suggested. Magn Reson Med 71:200–208, 2014. © 2013 Wiley Periodicals, Inc.</jats:p></jats:sec>