Calculated vs measured plasma osmolalities revisited.

書誌事項

公開日
1984-10-01
権利情報
  • https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model
DOI
  • 10.1093/clinchem/30.10.1703
公開者
Oxford University Press (OUP)

この論文をさがす

説明

<jats:title>Abstract</jats:title> <jats:p>The osmolalities of 100 plasma samples were measured and compared with the osmolalities calculated from the plasma concentrations (mmol/L) of sodium, potassium, glucose, and urea by several different formulae. The formula recommended by Dorwart and Chalmers (Clin Chem 21: 190, 1975) gave inferior results to those obtained with our "most accurate" formula: osmolality = 1.89 Na + 1.38 K + 1.03 urea + 1.08 glucose + 7.45. We recommend using this formula for calculation of osmolality on equipment linked to a computer. However, for simplicity, and to reduce the possibility of calculation errors, the following formula can be used for manual calculations: osmolality = 1.86 (Na + K) + glucose + urea + 10.</jats:p>

収録刊行物

  • Clinical Chemistry

    Clinical Chemistry 30 (10), 1703-1705, 1984-10-01

    Oxford University Press (OUP)

被引用文献 (1)*注記

もっと見る