A New Correlation of Pool-Boiling Data Including the Effect of Heating Surface Characteristics

説明

<jats:p>The standard approach which relates heat transfer in nucleate boiling to heat transfer to the superheated layer averaged over the time between two successive departures of a bubble from a given site is extended in order to relate the heat flux to the wall superheat through the heating surface characteristic. It was found that the q/A versus ΔT relation depends on the cavity size distribution over the surface. For a known distribution of cavity size, the q/A versus ΔT relation may be predicted, or for unknown characteristics of the boiling surface it is sufficient to have boiling data at one pressure in order to predict the q/A versus ΔT relation of other pressure levels for the same surface and the same liquid. The latter was tried on a wide range of experimental data including water and three organic liquids with good results.</jats:p>