大気圧イオン化質量分析法による室内空気中微量アセトンの定量
書誌事項
- タイトル別名
-
- Determination of trace amounts of acetone in room air by atmospheric pressure ionization MS.
- タイキアツ イオンカ シツリョウ ブンセキホウ ニヨル シツナイ クウキチュウ
この論文をさがす
抄録
Determination of trace amounts of acetone at (sub-ppm level) in air by atmospheric pressure ionization mass spectrometry (API-MS) was studied. Air samples were directly introduced to the ion source of the instrument without pre-concentration. This technique (positive mode) is also used for real-time analysis of air samples with rapid scanning, and has been shown to be highly sensitive for acetone (at sub-ppm levels). The peaks at m/z 19, 37, 55, 73, 91, corresponded to protonated water clusters of (H2O)H+, (H2O)2H+, (H2O)3H+, (H2O)4H+, and (H2O)5H+, respectively. The peak at m/z 47 was due to (C2H5OH)H+, and that at 59 due to ((CH3)2CO)H+ (acetone). They showed good repeatability with a relative standard deviation of less than about 5%. The API-MS voltage response produced a straight line in the approximate range 0.01 to 0.1 ppm of acetone in air.
収録刊行物
-