イオンクロマトグラフィーによる化粧品中の硫黄の定量

書誌事項

タイトル別名
  • 高速液体クロマトグラフィーの化粧品分析への応用 XI  イオンクロマトグラフィーによる化粧品中の硫黄の定量
  • Determination of sulfur in cosmetic products by ion chromatography
  • イオン クロマトグラフィー ニヨル ケショウヒンチュウ ノ イオウ ノ テイリ
  • 高速液体クロマトグラフィーの化粧品分析への応用(第11報)

この論文をさがす

説明

Sulfur in cosmetic products was successfully determined as sulfate ion by ion chromatography after oxidazation with hydrogen peroxide in an alkaline medium. One g of sample was taken into a 300ml beaker and dissolved in 30ml of pottasium hydroxideethanol solution on steam bath. After oxidizing with 50 ml of 3% hydrogen peroxide solution, 10ml ofphosphate solution (6mg/ml), internal standard, was added. The sample solution was diluted to ca. 300ml with water, and 15pi aliquot of the sample solution was injected into chromatograph equipped with a anion analytical column (6mm i. d. ×25cm) and a conductivity monitor by using 3.0mM sodium carbonate solution as a mobile phase. Peak height ratio (sulfate/phosphate) was directly proportional to weight ratio (sulfate/phosphate). Recovery rate and coeffi cient of variation of sulfur for the known sample was 98.9% and 1.70%, respectively. By using this method, sulfur in several commercial cosmetic products was accurately determined without any intereferences.

収録刊行物

  • 分析化学

    分析化学 32 (4), 224-228, 1983

    公益社団法人 日本分析化学会

被引用文献 (2)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ