メタルハライドランプにおける再点弧電圧の抑制

書誌事項

タイトル別名
  • Suppression of Reignition Voltage in Metal Halide Lamps
  • メタル ハライド ランプ ニ オケル サイ テンコ デンアツ ノ ヨクセイ

この論文をさがす

抄録

Reignition phenomena in metal halide lamps during warm-up have been investigated.<BR>Two probes were set between two main electrodes and space potentials were measured at the moment when reignition occurred. Reignition voltage were measured using an arc tube of which electrodes gap was variable.<BR>These experiments showed that reignition voltage grew uniformly in the electrodes gap.<BR>Reignition voltage during warm-up can be suppressed by the following means.<BR>(1) To dose excess metal into arc tube.<BR>(2) To make raporization of mercury faster than that of metal halid<BR>(3) To put the inert gas at high pressures.<BR>(4) To use heavy inert gas.

収録刊行物

  • 照明学会誌

    照明学会誌 68 (6), 265-270, 1984

    一般社団法人 照明学会

詳細情報 詳細情報について

問題の指摘