Tribological Properties of Nitrogen Ion Implanted Ti Alloy.

Bibliographic Information

Other Title
  • 窒素イオン注入したTi合金のトライボロジー特性
  • チッソ イオン チュウニュウシタ Ti ゴウキン ノ トライボロジー トクセイ

Search this article

Abstract

In order to investigate the mechanical properties of ion-implanted Ti alloy (Ti-6Al-4V), disk samples of Ti-6Al-4V were implanted with 200keV N2+ ions at doses of 2.5×1016 to 5×1017 ions/cm2. Tribological properties were evaluated with pin-on-disk tests. Bearing steel (SUJ2) balls 5mm in diameter were used as pins. Sliding conditions were as follows: load, 0.46N; speed, 0.04m/s; oil lubrication, SAE 7.5W-30.<br>Knoop hardness (load: 98mN) increased from Hk 356 to Hk 556 (dose: 5×1017ions/cm2) with ion dosage. The coefficient of friction of N2+ ion-implanted Ti-6Al-4V disks ranged from 0.1 to 0.2, values that were lower than 0.6 obtained for an unimplanted disk. N2+ ion implantation reduced wear on the pins as well as on the Ti-6Al-4V disks. The seizure load of N2+ ion-implanted disks increased with ion dosage.

Journal

Citations (4)*help

See more

References(5)*help

See more

Details 詳細情報について

Report a problem

Back to top