Miniaturized Membrane Sensors for the Determination of Rivastigmine Hydrogen Tartrate
-
- El-Kosasy Amira Mabrouk
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University
-
- Salem Maissa Yacoub
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University
-
- El-Bardicy Mohamed Galal
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University
-
- El-Rahman Mohamed Khaled Abd
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University
Search this article
Description
Novel miniaturized polyvinyl chloride (PVC) membrane sensors in all-solid state graphite and platinum wire supports were developed, electrochemically evaluated and used for the assay of rivastigmine hydrogen tartrate drug (RIV). The RIV sensors are based on the formation of an ion-association complex between the drug cation and tetrakis(4-chlorophenyl)borate (TpClPB) anionic exchanger as electroactive material dispersed in a PVC matrix. Linear responses of 10−2—10−5 M and 10−2—10−4 M with cationic slopes of 56.4 mV and 53.6 mV over the pH range 4—7 were obtained by using the RIV-coated graphite (sensor 1) and platinum wire (sensor 2) membrane sensors, respectively. The proposed method displays useful analytical characteristics for the determination of RIV in Exelon® capsules with average recoveries of 100.01±0.835, 100.09±0.896, and in plasma with average recoveries of 99.47±0.97, 99.58±0.82, and in rat brain homogenate with average recoveries of 98.16±1.62, 99.02±1.57, for sensors 1 and 2, respectively. The methods were also used to determine the intact drug in the presence of its degradation product and thus could be used as stability indicating methods. The results obtained by the proposed procedures were statistically analyzed and compared with those obtained by using a reported method. No significant difference for both accuracy and precision was observed.
Journal
-
- Chemical and Pharmaceutical Bulletin
-
Chemical and Pharmaceutical Bulletin 56 (6), 753-757, 2008
The Pharmaceutical Society of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204170054528
-
- NII Article ID
- 110006684270
-
- NII Book ID
- AA00602100
-
- ISSN
- 13475223
- 00092363
-
- NDL BIB ID
- 9508556
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed