- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Effect of the Fresnel membranous prism on the visual function.
-
- Tsurudome Yasuhiro
- Osaka University
-
- Asonuma Sanae
- Osaka University
-
- Kojima Yuka
- Osaka University
-
- Nakamae Mika
- Osaka University
-
- Kanayama Motoko
- Osaka University
-
- Fujiki Kaori
- Osaka University
-
- Amano Daisuke
- Osaka University
-
- Oka Tomoko
- Osaka University
-
- Osawa Yui
- Osaka University
-
- Takada Yusuke
- Osaka University
-
- Bessho Kenichiro
- Yodogawa Christian Hospital
-
- Fujikado Takashi
- Osaka University
Bibliographic Information
- Other Title
-
- フレネル膜プリズムの視機能への影響について
Search this article
Description
[Purpose] To examine the effect of Fresnel prism on visual function.<br>[Subject and method] 9 eyes of 9 subjects without ocular abnormalities were examined . Age ranged from 21 to 29 years (24.8±3.12, average±SD) and the refraction ranged from +0.5 to -5.0 diopters (-1.47±1.63). Membrane prism was fixed on the full-corrected lens. The power of Fresnel prisms were (1) 6 (2) 8 (3) 10 (4) 12 (5) 15 (6) 20 (7) 30 (Prism, Base out). We tested, 1: Full-corrected visual acuity, 2: Contrast sensitivity (Area Under Log Contrast Sensitivity Function, CSV-1000E), 3: Glare test (CSV1000-HGT) 4: Root Mean Square (μm) value of total ocular aberration (Coma like (C3) aberration, Spherical-like (C4) aberration, C3+C4) and scatter index (SI) by Wavefront analyzer (TOPCON KR-9000PW) 5: Questionnaires of visual quality with prism.<br>[Results] Visual acuity and contrast sensitivity decreased significantly with prism 8Δ or more as compared with no prism (P<0.01). With glare light, contrast sensitivity decreased significantly with prism 12Δ or more compared without prism(P<∼0.05). Contrast sensitivity with glare light decreased significantly with prism 8Δor more compared with it without glare light (P=∼0.05). C3+C4 increased with prism 12Δ and 30Δsignificantly compared without prism (P<0.05). SI increased significantly with prism 12Δ or more(P<0.05). The subjective visual quality decreased with the increase of the power of prism.<br>[Conclusion] When we prescribe Fresnel membrane prisms with a power more than 8Δ, we have to consider the deterioration of visual function such as visual acuity, contrast sensitivity, glare.
Journal
-
- JAPANESE ORTHOPTIC JOURNAL
-
JAPANESE ORTHOPTIC JOURNAL 36 85-93, 2007
JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204247374208
-
- NII Article ID
- 130003646108
- 10019964235
-
- NII Book ID
- AN10084015
-
- ISSN
- 18839215
- 03875172
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed