Electrocatalytic Characteristics of a 1-[4-(Ferrocenyl ethynyl)phenyl]-1-ethanone Modified Carbon-Paste Electrode in the Oxidation of Ascorbic Acid

DOI PDF Web Site Web Site Web Site ほか1件をすべて表示 一部だけ表示 被引用文献4件 参考文献78件
  • RAOOF Jahan-Bakhsh
    Electroanalytical Chemistry Research Laboratory, Department of Chemistry, Faculty of Basic Sciences, Mazandaran University
  • OJANI Reza
    Electroanalytical Chemistry Research Laboratory, Department of Chemistry, Faculty of Basic Sciences, Mazandaran University
  • HOSSEINZADEH Rahman
    Electroanalytical Chemistry Research Laboratory, Department of Chemistry, Faculty of Basic Sciences, Mazandaran University
  • GHASEMI Vallyallah
    Electroanalytical Chemistry Research Laboratory, Department of Chemistry, Faculty of Basic Sciences, Mazandaran University

この論文をさがす

説明

A carbon-paste electrode spiked with 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone was constructed by the incorporation of 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone in a graphite powder silicon oil matrix. It shown by cyclic voltammetry and double potential-step chronoamperometry, which this ferrocene derivative modified a carbon-paste electrode, can catalyze the ascorbic acid oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 7.00), the oxidation of ascorbic acid at the surface of this carbon paste modified electrode occurs at a potential of about 260 mV less positive than that of an unmodified carbon-paste electrode. The catalytic oxidation peak current was linearly dependent on the ascorbic acid concentration, and a linear calibration curve was obtained in the range of 6 × 10-5 M - 7 × 10-3 M of ascorbic acid with a correlation coefficient of 0.9997. The detection limit (2σ) was determined to be 6.3 × 10-5 M. This method was also used for the determination of ascorbic acid in some pharmaceutical samples, such as effervescent tablets, ampoules and multivitamin syrup, by using a standard addition method. The reliability of the method was established by a parallel determination against the official method.termined to be 6.3 × 10-5 M. This method was also used for the determination of ascorbic acid in some pharmaceutical samples, such as effervescent tablets, ampoules and multivitamin syrup, by using a standard addition method. The reliability of the method was established by a parallel determination against the official method.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 19 (9), 1251-1258, 2003

    社団法人 日本分析化学会

被引用文献 (4)*注記

もっと見る

参考文献 (78)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ