Determination of Nucleic Acids Using Calcein-Neodymium Complex as a Fluorescence Probe.

DOI PDF Web Site Web Site Web Site ほか1件をすべて表示 一部だけ表示 参考文献17件
  • ZHU Zhancai
    Department of Chemistry, Zhangzhou Teacher’s University

この論文をさがす

抄録

A novel fluorometric method has been developed for rapid determination of DNA and RNA with calcein-neodymium complex as a fluorescence probe. The method is based on the fluorescence enhancement of calcein-Nd(III) complex in the presence of DNA or RNA, with maximum excitation and emission wavelength at 489 nm and 514 nm, respectively. Under optimal conditions, the calibration graphs are linear over the range 0.5 - 3.0 μg/ml for both DNA and yeast RNA, 0.4 - 2.0 μg/ml for fish sperm DNA (FS DNA) and 0 - 3.0 μg/ml for calf thymus DNA (CT DNA). The corresponding detection limits are 15.1 ng/ml for DNA, 21.2 ng/ml for yeast RNA, 10.5 ng/ml for FS DNA and 8.9 ng/ml for CT DNA. The interaction mechanism for the binding of calcein-Nd(III) complex to DNA is also studied. The results of absorption spectra, fluorescence polarization measurements and thermal denaturation experiments, suggested that the interaction between calcein-Nd(III) complex and DNA is an electrostatic interaction.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 17 (12), 1375-1377, 2001

    社団法人 日本分析化学会

参考文献 (17)*注記

もっと見る

キーワード

詳細情報 詳細情報について

問題の指摘

ページトップへ