Ultra-sensitive Trace-Water Optical Sensor with In situ-synthesized Metal-Organic Framework in Glass Paper
-
- OHIRA Shin-Ichi
- Department of Chemistry, Kumamoto University
-
- NAKAMURA Nao
- Department of Chemistry, Kumamoto University Tsukuba Laboratories, Taiyo Nippon Sanso Corporation
-
- ENDO Masaaki
- Tsukuba Laboratories, Taiyo Nippon Sanso Corporation
-
- MIKI Yusuke
- Tsukuba Laboratories, Taiyo Nippon Sanso Corporation
-
- HIROSE Yasuo
- Tsukuba Laboratories, Taiyo Nippon Sanso Corporation
-
- TODA Kei
- Department of Chemistry, Kumamoto University
書誌事項
- タイトル別名
-
- Ultra-sensitive Trace-Water Optical Sensor with <i>In situ</i>- synthesized Metal–Organic Framework in Glass Paper
この論文をさがす
抄録
Monitoring of trace water in industrial gases is strongly recommended because contaminants cause serious problems during use, especially in the semiconductor industry. An ultra-sensitive trace-water sensor was developed with an in situ-synthesized metal–organic framework as the sensing material. The sample gas is passed through the sensing membrane and efficiently and rapidly collected by the sensing material in the newly designed gas collection/detection cell. The sensing membrane, glass paper impregnated with copper 1,3,5-benzenetricarboxylate (Cu-BTC), is also newly developed. The amount and density of the sensing material in the sensing membrane must be well balanced to achieve rapid and sensitive responses. In the present study, Cu-BTC was synthesized in situ in glass paper. The developed system gave high sensing performances with a limit of detection (signal/noise ratio = 3) of 9 parts per billion by volume (ppbv) H2O and a 90% response time of 86 s for 200 ppbv H2O. The reproducibility of the responses within and between lots had relative standard deviations for 500 ppbv H2O of 0.8% (n = 10) and 1.5% (n = 3), respectively. The long-term (2 weeks) stability was 7.3% for 400 ppbv H2O and one-year continuous monitoring test showed the sensitivity change of <∼3% before and after the study. Furthermore, the system response was in good agreement with the response achieved in cavity ring-down spectroscopy. These performances are sufficient for monitoring trace water in industrial gases. The integrated system with light and gas transparent structure for gas collection/absorbance detection can also be used for other target gases, using specific metal–organic frameworks.
収録刊行物
-
- Analytical Sciences
-
Analytical Sciences 34 (4), 495-500, 2018
社団法人 日本分析化学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204260641536
-
- NII論文ID
- 130006682640
-
- NII書誌ID
- AA10500785
-
- ISSN
- 13482246
- 09106340
-
- NDL書誌ID
- 028942686
-
- PubMed
- 29643314
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- PubMed
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可