Simple Determination of L-Ascorbic Acid on TLC by Visual Detection Using Autocatalytic Reaction

DOI PDF Web Site Web Site Web Site View 1 Remaining Hide 49 References

Search this article

Abstract

The L-ascorbic acid concentration in beverages was measured after separation by silica gel thin layer chromatography (TLC) by visually determining the time in autocatalytic reaction for the L-ascorbic acid spot to turn the same yellow color of the background and disappear (the end time of the induction period) after spraying the slide with a 3,6-dihydroxyxanthane solution. There was a good linear relationship between the end time of the induction period and the concentration of L-ascorbic acid for concentrations in the range of 5.0 – 20 mM (r2 = 0.9944). In addition, there was a good relationship expressed by a quadratic equation in the concentration range of 0.1 – 5.0 mM (r2 = 0.9975). The relative standard deviations of the L-ascorbic acid values for 3 beverages (2.2 – 8.6 mM) were less than 5% (n = 5), and the recovery of 5.0 mM L-ascorbic acid from 4 beverages (0.7 – 7 mM) was 97 – 110%. A good correlation was also observed between the L-ascorbic acid values of 23 beverages (0 – 86 mM) determined by the proposed TLC method and the colorimetric method contained in a commercially available kit for L-ascorbic acid (r2 = 0.9945).

Journal

  • Analytical Sciences

    Analytical Sciences 29 (5), 505-509, 2013

    The Japan Society for Analytical Chemistry