Experimental Consideration of Capillary Chromatography Based on Tube Radial Distribution of Ternary Mixture Carrier Solvents under Laminar Flow Conditions

DOI PDF Web Site Web Site Web Site ほか1件をすべて表示 一部だけ表示 被引用文献15件 参考文献44件
  • JINNO Naoya
    Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering, Doshisha University
  • HASHIMOTO Masahiko
    Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering, Doshisha University
  • TSUKAGOSHI Kazuhiko
    Department of Chemical Engineering and Materials Science, Faculty of Science and Engineering, Doshisha University

この論文をさがす

抄録

A capillary chromatography system has been developed based on the tube radial distribution of the carrier solvents using an open capillary tube and a water–acetonitrile–ethyl acetate mixture carrier solution. This tube radial distribution chromatography (TRDC) system works under laminar flow conditions. In this study, a phase diagram for the ternary mixture carrier solvents of water, acetonitrile, and ethyl acetate was constructed. The phase diagram that included a boundary curve between homogeneous and heterogeneous solutions was considered together with the component ratios of the solvents in the homogeneous carrier solutions required for the TRDC system. It was found that the TRDC system performed well with homogeneous solutions having component ratios of the solvents that were positioned near the homogeneous-heterogeneous solution boundary of the phase diagram. For preparing the carrier solutions of water–hydrophilic/hydrophobic organic solvents for the TRDC system, we used for the first time methanol, ethanol, 1,4-dioxane, and 1-propanol, instead of acetonitrile (hydrophilic organic solvent), as well as chloroform and 1-butanol, instead of ethyl acetate (hydrophobic organic solvent). The homogeneous ternary mixture carrier solutions were prepared near the homogeneous-heterogeneous solution boundary. Analyte mixtures of 2,6-naphthalenedisulfonic acid and 1-naphthol were separated with the TRDC system using these homogeneous ternary mixture carrier solutions. The pressure change in the capillary tube under laminar flow conditions might alter the carrier solution from homogeneous in the batch vessel to heterogeneous, thus affecting the tube radial distribution of the solvents in the capillary tube.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 27 (3), 259-, 2011

    社団法人 日本分析化学会

被引用文献 (15)*注記

もっと見る

参考文献 (44)*注記

もっと見る

キーワード

詳細情報 詳細情報について

問題の指摘

ページトップへ