Development of an Albumin Copper Binding (ACuB) Assay to Detect Ischemia Modified Albumin

DOI PDF Web Site Web Site Web Site ほか1件をすべて表示 一部だけ表示 参考文献37件
  • EOM Ji-Eun
    College of Pharmacy, Graduate School of Pharmaceutical Sciences, Ewha Global Top 5 Program, Ewha Womans University
  • LEE Eunyoung
    College of Pharmacy, Graduate School of Pharmaceutical Sciences, Ewha Global Top 5 Program, Ewha Womans University
  • JEON Kyung-Hwa
    College of Pharmacy, Graduate School of Pharmaceutical Sciences, Ewha Global Top 5 Program, Ewha Womans University
  • SIM Jeongeun
    Department of Biological Science, Sungkyunkwan University
  • SUH Minah
    Department of Biological Science, Sungkyunkwan University
  • JHON Gil-Ja
    Department of Chemistry and Nano Science, Ewha Womans University
  • KWON Youngjoo
    College of Pharmacy, Graduate School of Pharmaceutical Sciences, Ewha Global Top 5 Program, Ewha Womans University

この論文をさがす

抄録

Myocardial ischemia (MI) induces many changes in the body, including pH decrease and electrolyte imbalance. No obvious symptoms of MI appear until irreversible cellular injuries occur. Since early treatment is critical for recovery from ischemia, the development of reliable diagnostic tool is demanded to detect the early ischemic status. Ischemia modified albumin (IMA), formed by cleavage of the last two amino acids of the human serum albumin (HSA) N-terminus, has been considered so far as the most trustworthy and accurate marker for the investigation of ischemia. IMA levels are elevated in plasma within a few minutes of ischemic onset, and may last for up to 6 h. In the present study, we developed a novel assay for the examination of IMA levels to ameliorate the known albumin cobalt binding (ACB) test established previously. We observed a stronger copper ion bound to the HSA N-terminal peptide than cobalt ion by HPLC and ESI-TOF mass spectrometric analyses. The copper ion was employed with lucifer yellow (LY), a copper-specific reagent to develop a new albumin copper binding (ACuB) assay. The parameters capable of affecting the assay results were optimized, and the finally-optimized ACuB assay was validated. The result of the IMA level measurement in normal versus stroke rat serum suggests that the ACuB assay is likely to be a reliable and sensitive method for the detection of ischemic states.

収録刊行物

  • Analytical Sciences

    Analytical Sciences 30 (10), 985-990, 2014

    社団法人 日本分析化学会

参考文献 (37)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ