Pretreatment Method for Immunoassay of Polychlorinated Biphenyls in Transformer Oil Using Multilayer Capillary Column and Microfluidic Liquid–Liquid Partitioning
-
- AOTA Arata
- Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry
-
- DATE Yasumoto
- Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry Graduate School of Environmental Studies, Tohoku University
-
- TERAKADO Shingo
- Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry
-
- OHMURA Naoya
- Environmental Science Research Laboratory, Central Research Institute of Electric Power Industry
この論文をさがす
抄録
Polychlorinated biphenyls (PCBs) are persistent organic pollutants that are present in the insulating oil inside a large number of transformers. To aid in eliminating PCB-contaminated transformers, PCBs in oil need to be measured using a rapid and cost-effective analytical method. We previously reported a pretreatment method for the immunoassay of PCBs in oil using a large-scale multilayer column and a microchip with multiple microrecesses, which permitted concentrated solvent extraction. In this paper, we report on a more rapid and facile pretreatment method, without an evaporation process, by improving the column and the microchip. In a miniaturized column, the decomposition and separation of oil were completed in 2 min. PCBs can be eluted from the capillary column at concentrations seven-times higher than those from the previous column. The total volume of the microrecesses was increased by improving the microrecess structure, the enabling extraction of four-times the amount of PCBs achieved with the previous system. By interfacing the capillary column with the improved microchip, PCBs in the eluate from the column were extracted into dimethyl sulfoxide in microrecesses with high enrichment and without the need for evaporation. Pretreatment was completed within 20 min. The pretreated oil was analyzed using a flow-based kinetic exclusion immunoassay. The limit of detection of PCBs in oil was 0.15 mg kg−1, which satisfies the criterion set in Japan of 0.5 mg kg−1.
収録刊行物
-
- Analytical Sciences
-
Analytical Sciences 29 (4), 393-399, 2013
社団法人 日本分析化学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390001204261671168
-
- NII論文ID
- 10031165328
-
- NII書誌ID
- AA10500785
-
- COI
- 1:STN:280:DC%2BC3srkt1yitw%3D%3D
-
- ISSN
- 13482246
- 09106340
-
- NDL書誌ID
- 024405283
-
- PubMed
- 23574664
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- PubMed
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可