書誌事項
- タイトル別名
-
- Repair of a Medial Orbital Wall Fracture in the Ethmoid Sinus Using a Balloon Catheter.
この論文をさがす
抄録
A patient with a broad medial orbital blowout fracture was treated surgically by the balloon catheter technique.<br>After repair of the medial orbital wall through a transorbital approach with an external incision, a balloon catheter was inserted into the anterior and posterior ethmoid sinus by the endonasal approach to repair the medial orbital wall of the blowout fracture. The catheter was left in for nineteen days. Satisfactory results were obtained.<br>The balloon catheter technique is quite simple and useful in the repair of fractures of the medial orbital wall.
収録刊行物
-
- 耳鼻咽喉科臨床
-
耳鼻咽喉科臨床 89 (4), 449-453, 1996
耳鼻咽喉科臨床学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204261958912
-
- NII論文ID
- 10005932050
-
- NII書誌ID
- AN00107089
-
- ISSN
- 18844545
- 00326313
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可