Subjective Scaling of Hand-Arm Vibration
-
- MAEDA Setsuo
- Measurement and Control of Work Environment Research Group, National Institute of Occupational Safety and Health
-
- SHIBATA Nobuyuki
- Measurement and Control of Work Environment Research Group, National Institute of Occupational Safety and Health
Search this article
Description
The purpose of this research was to establish a scale for comfort with regard to hand-arm vibration using the category judgment method and to validate the frequency-weighting method of the ISO 5349-1 standard. Experiments were conducted using random signals as stimuli. These stimuli consisted of three types of signal, namely designated stimulus F, with flat power spectrum density (PSD) ranging from 1 to 1,000 Hz, stimulus H with PSD which became 20 dB higher at 1,000 Hz than at 1 Hz, and stimulus L that had a PSD 20 dB lower at 1,000 Hz. These stimuli were selected from the specific spectrum patterns of hand-held vibration tools. These signals were modified by the Wh frequency weighting in accordance with ISO 5349-1, and the R.M.S. values were adjusted to be equal. In addition, the signal levels were varied over a range of five steps to create 15 kinds of individual stimuli. The subjects sat in front of a vibrator and grasped the mounted handle which exposed them to vertical vibrations after which they were asked to choose a numerical category to best indicate their perceived level of comfort (or otherwise) during each stimulus. From the experimental results of the category judgment method, the relationship between the psychological values and the frequency-weighted R.M.S. acceleration according to the ISO 5349-1 standard was obtained. It was found that the subjective response scaling of hand-arm vibration can be used for design-objective values of hand-held tool vibration.<br>
Journal
-
- Industrial Health
-
Industrial Health 46 (2), 118-124, 2008
National Institute of Occupational Safety and Health
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204280992512
-
- NII Article ID
- 130004483281
- 40015971021
-
- NII Book ID
- AA00672955
-
- ISSN
- 18808026
- 00198366
-
- NDL BIB ID
- 9457052
-
- PubMed
- 18413964
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed