Water leaching test procedure to measure the solid content of fire-retardant in treated wood
-
- KAMIKAWA Daisuke
- Forestry and Forest Products Research Institute
Bibliographic Information
- Other Title
-
- 難燃薬剤処理木材の溶脱法による薬剤固形成分量の計測手法に関する研究
- ナンネンヤクザイ ショリ モクザイ ノ ヨウ ダッポウ ニ ヨル ヤクザイコケイセイ ブンリョウ ノ ケイソク シュホウ ニ カンスル ケンキュウ
Search this article
Description
As a way to measure the solid content of fire-retardant in treated wood, we suggested to calculate it from the weight change of samples with water leaching. Thin samples of 5 wood species (Sugi, Akamatsu, Karamatsu, Douglas Fir and Western Hemlock) were treated with several concentration impregnant and water leaching test was conducted with these treated samples. It was indicated that the correction against elution from base material wood was needed for Karamatsu samples to derive the solid content of fire-retardant from weight change after the fire-retardant treatment or water leaching operation. The effects of leaching condition and drying temperature were examined, and appropriate leaching conditions were demonstrated. Additionally, we suggested the way to predict the solid content of fire-retardant from density of base wood.
Journal
-
- MOKUZAI HOZON (Wood Protection)
-
MOKUZAI HOZON (Wood Protection) 39 (2), 78-85, 2013
JAPAN WOOD PRESERVING ASSOCIATION
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204293422720
-
- NII Article ID
- 10031165435
-
- NII Book ID
- AN00240373
-
- ISSN
- 18840116
- 02879255
-
- NDL BIB ID
- 024577670
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- IRDB
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed