塩酸処理ポリウレタンフォームを用いるクロム(VI)の固相抽出

書誌事項

タイトル別名
  • Solid-Phase Extraction of Chromium(VI) by Polyurethane Foam Treated with Hydrochloric Acid
  • 塩酸処理ポリウレタンフォームを用いるクロム(6)の固相抽出
  • エンサン ショリ ポリウレタンフォーム オ モチイル クロム 6 ノ コソウ チュウシュツ

この論文をさがす

抄録

Chromium exists widely in nature as both trivalent and hexavalent forms. Although, Cr(III) is an essential element for humans at trace levels, Cr(VI) has great toxicity and carcinogenicity at low concentrations. Cr(VI) is typically present in aqueous solutions, such as CrO42− anion. Polyurethane foam (PUF) was impregnated with hydrochroric acid (HCl-PUF) and then used to remove Cr(VI) from environmental water samples. However, Cr(VI) was not adsorbed on PUF, Cr(VI) was adsorbed on HCl-PUF. In this study, the adsorption conditions of Cr(VI) on HCl-PUF were investigated, such as the adsorption time and the solution pH. Further, the deadsorption conditions of Cr(VI) from HCl-PUF were investigated, such as the kind of eluents and their concentrations. Cr(VI) was quantitatively adsorbed on HCl-PUF at a pH range 3.0-8.0 from aqueous solutions and their adsorption isotherms were fitted by the Freundlich equation. The Cr(VI) adsorbed on HCl-PUF as eluted with 3.0 mol dm−3 nitric acid. The property of HCl-PUF was extended to the preconcentration and determination of trace amounts of Cr(VI) in water samples by Inductively Coupled Plasma Emission Spectrometry (ICP-AES).

収録刊行物

  • 分析化学

    分析化学 59 (12), 1163-1167, 2010

    公益社団法人 日本分析化学会

被引用文献 (3)*注記

もっと見る

参考文献 (44)*注記

もっと見る

関連プロジェクト

もっと見る

詳細情報 詳細情報について

問題の指摘