- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Determination of Trace Elements in Scallop and Fish Otolith by Instrumental Neutron Activation Analysis Using Anti-Coincidence and Coincidence Counting Methods
-
- SUZUKI Shogo
- Faculty of Engineering, Musashi Institute of Technology
-
- OKADA Yukiko
- Faculty of Engineering, Musashi Institute of Technology
-
- HIRAI Shoji
- Faculty of Engineering, Musashi Institute of Technology
Bibliographic Information
- Other Title
-
- 反同時・同時計数法を用いる機器中性子放射化分析法によるホタテ及び魚耳石中の微量元素の定量
- ハン ドウジ ドウジ ケイスウホウ オ モチイル キキ チュウセイシ ホウシャカ ブンセキホウ ニ ヨル ホタテ オヨビ ギョ ジセキ チュウ ノ ビリョウ ゲンソ ノ テイリョウ
Search this article
Description
Trace element concentrations in scallop reference material and fish otolith certified reference materials prepared at the National Institute for Environmental Studies (NIES) of Japan were determined by instrumental neutron activation analysis (INAA). Nine aliquots of scallop sample (ca. 252∼507 mg) and five aliquots of fish otolith sample (ca. 502∼988 mg) and comparative standards were irradiated for a short time (10 s) at a thermal neutron flux of 1.5 × 1012 n cm−2 s−1 (pneumatic transfer) and for a long time (6 h) at a thermal neutron flux of 3.7 × 1012 n cm−2 s−1 (central thimble) in the Rikkyo University Research Reactor (100 kW). The irradiated samples were measured by conventional γ-ray spectrometry using a coaxial Ge detector, and by anti-coincidence and coincidence γ-ray spectrometry with a coaxial Ge detector and a well-type NaI(Tl) detector to determine as many trace elements as possible with high sensitivity. The concentrations of 34 elements of the NIES No.15 scallop referrence material and 16 elements of the NIES No.22 fish otolith CRM were determined. Using the coincidence counting method to determine Se, Ba and Hf, the lower limit of the determination was improved by 2 times compared with the conventional counting method.<br>
Journal
-
- BUNSEKI KAGAKU
-
BUNSEKI KAGAKU 54 (7), 605-612, 2005
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390001204355297024
-
- NII Article ID
- 110002910106
-
- NII Book ID
- AN00222633
-
- COI
- 1:CAS:528:DC%2BD2MXmtlWrsrs%3D
-
- NDL BIB ID
- 7420716
-
- ISSN
- 05251931
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- NDL Digital Collections (NII-ELS)
- CiNii Articles
-
- Abstract License Flag
- Disallowed