- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Estimation of Carbon Aromaticity for Asphaltenes through Elemental Analysis and Proton NMR: Carbon Aromaticity of Pentane-insoluble and Heptane-soluble Fraction
-
- SATO Shinya
- Energy Technology Research Institute, National Institute of Advanced Industrial Science and Technology
Bibliographic Information
- Other Title
-
- アスファルテンの炭素芳香族性の元素分析およびプロトンNMRからの予測:ペンタン不溶‐ヘプタン可溶分の炭素芳香族性
- アスファルテンの炭素芳香族性の元素分析およびプロトンNMRからの予測--ペンタン不溶-ヘプタン可溶分の炭素芳香族性
- アスファルテン ノ タンソ ホウコウゾクセイ ノ ゲンソ ブンセキ オヨビ プロトン NMR カラ ノ ヨソク ペンタン フヨウ ヘプタン カヨウ ブン ノ タンソ ホウコウゾクセイ
Search this article
Description
The structure of asphaltene is an important factor in the reactivity of heavy hydrocarbons, with. elemental analysis and nuclear magnetic resonance (NMR) spectrometry commonly used to evaluate its structure. However, such analyses can be limited by small sample amounts. In particular, 13C-NMR for the determination of carbon aromaticity (fa) requires about 100 mg of asphaltene, whereas elemental analysis and 1H-NMR need only 10 mg or less. In addition, 13C-NMR has the disadvantage of a long time. To avoid these drawbacks, we used a statistical estimation method to determine the fa of the pentane-insoluble and hepane-soluble fraction (C5AS) based on the results of elemental analysis and 1H-NMR analysis using 29 worldwide vacuum resides. Results showed that the fa was estimated within an error of 0.03 using H/C, N/C and S/C atomic ratios obtained by an elemental analysis, and hydrogen distribution obtained by 1H-NMR. The difference between the observed and estimated number of aromatic rings per unit structure was expected to be within 1. This method can estimate the fa for C5AS using a sample of only 20-30 mg, and the structural analysis is more accurate than that without fa value.
Journal
-
- Journal of the Japan Institute of Energy
-
Journal of the Japan Institute of Energy 90 (3), 274-276, 2011
The Japan Institute of Energy
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204357385216
-
- NII Article ID
- 130004741193
-
- NII Book ID
- AN10373883
-
- ISSN
- 18826121
- 09168753
-
- NDL BIB ID
- 11049532
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed