<b>The Uncertainty on using Graduated Volumetric Glassware for the Concentration of </b><b>Samples (Concentration Tube) and its Effect on Measurement Accuracy </b>
-
- MATSUDA Shirou
- Sakai City Institute of Public Health
-
- IHARA Yutaka
- Sakai City Institute of Public Health
-
- MIYAGAWA Hajime
- Sakai City Institute of Public Health
-
- KOMORI Takao
- Sakai City Institute of Public Health
-
- TABATA Kayo
- Sakai City Institute of Public Health
-
- SHINTO Masanori
- Sakai City Institute of Public Health
-
- KOBAYASHI Kazuo
- Sakai City Institute of Public Health
-
- TANAKA Tomoyuki
- Sakai City Institute of Public Health
Bibliographic Information
- Other Title
-
- 濃縮操作の定容に用いる目盛り付きガラス製器具(「濃縮管」)の不確かさと測定精度への影響
- ノウシュク ソウサ ノ テイヨウ ニ モチイル メモリ ツキ ガラスセイ キグ(「 ノウシュクカン 」)ノ フ タシカ サ ト ソクテイ セイド エ ノ エイキョウ
Search this article
Description
Although each step in the quantitative analysis of trace substances is susceptible to marked variability, it is assumed that there is only a negligible difference in the quality of concentration tubes, and that the concentration step, which is performed in such tubes under a nitrogen gas stream to obtain the desired volume, generates very few sources of variation. Therefore, using a quantitative method for measuring benzo(a)pyrene (B(a)P) as a test procedure, we estimated uncertainties involved in each step, from sampling to instrumental analysis, and evaluated the effect of concentration tubes on the measurement accuracy based on an uncertainty analysis. As the results, the combined relative standard uncertainty for the determination of 1.0 mg/L of (B(a)P) was 3.3-5.4%, of which the contribution of concentration tubes was 67.3-87.8%. The present study demonstrated that uncertainty on use of concentration tubes affects measurement accuracy, and highlighted the need to introduce precision control in vessel use.
Journal
-
- Journal of Environmental Chemistry
-
Journal of Environmental Chemistry 25 (2), 101-107, 2015
Japan Society for Environmental Chemistry
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204368400896
-
- NII Article ID
- 130005113926
-
- NII Book ID
- AN10547099
-
- ISSN
- 18825818
- 09172408
-
- NDL BIB ID
- 026561728
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed