Consumption of Electric Energy and Water for Eggplant Plug Transplant Production in a Closed-type Transplant Production System.

Bibliographic Information

Other Title
  • 閉鎖型苗生産システムのナスセル成型苗育成時における電気エネルギおよび水消費量
  • ヘイサガタ ナエ セイサン システム ノ ナスセル セイケイ ナエ イクセイジ ニ オケル デンキ エネルギ オヨビ ミズ ショウヒリョウ

Search this article

Abstract

Eggplant (Solanum melongena L., cv. Senryounigou) plug transplants were grown for 17 days in a closed-type transplant production system at photosynthetic photon flux on the tray surface of 0, 100 and 350 μmol m-2s-1 on days 0-3, 4-6 and 7-16, respectively, air temperature of 30/ 20°C, (photoperiod/dark period) CO2 concentration of 1000 μmol mol-1 (photoperiod), relative humidity of 80/100% (photoperiod/dark period) and photoperiod of 16 h d-1. The electric energy consumption per transplant was 0. 35 MJ (0. 1 kWh) and its cost was 1. 4-1. 5 Japanese Yen. The period required for transplant production was about 2 weeks shorter in the closed-type transplant production system than in the open-type transplant production system (i.e. the greenhouse). The amount of consumed water per tray area in the closed-type transplant production system would be reduced from 65. 8 to 12. 3 kg m-2 by reusing dehumidified water for irrigation. These results show that the closed-type transplant production system is feasible for commercialization.

Journal

  • Shokubutsu Kojo Gakkaishi

    Shokubutsu Kojo Gakkaishi 13 (1), 1-6, 2001

    JAPANESE SOCIETY OF AGRICULTURAL, BIOLOGICAL AND ENVIRONMENTAL ENGINEERS AND SCIENTISTS

Citations (5)*help

See more

References(14)*help

See more

Details 詳細情報について

Report a problem

Back to top