Evaluation of the Availability for Filter Zone Material by the Dirty-Water Test

  • YAMADA Satoshi
    日本工営株式会社 仙台支店 技術第一部(前・株式会社クレアリア 河川技術部)

Bibliographic Information

Other Title
  • DW試験によるフィルター材の適用性評価
  • DW シケン ニ ヨル フィルターザイ ノ テキヨウセイ ヒョウカ

Search this article

Abstract

One of the roles of filter zone of rock fill dam is to prevent core zone material from being flowed out. This function is expressed under the condition that grading relation of core and filter zone material satisfies the Filter law and permeability coefficient of filter zone is from 10 to 100 times of that of core zone. As a result of preliminary examination conducted in advance of filling test at Tono dam locating within administrative area of Chugoku Regional Development Bureau, grading of core and filter zone material satisfied the Filter law but permeability coefficient of filter zone was more than 100 times of that of core zone. Due to this result, the Dirty-Water Test for this filter zone material was conducted to evaluate its availability for filter zone.