書誌事項
- タイトル別名
-
- Study on Convective Heat Transfer from Hot Water to Cold Air Flow with Evaporation
- コウオンスイ カラ レイクウキリュウ エ ノ ジョウハツ デンネツ キョウゾン タイリュウ ネツ デンタツ ニ カンスル ケンキュウ
この論文をさがす
説明
Evaporation heat transfer from the hot water flow to the cold air flow in a horizontal duct was examined. Hot water was in the range of 35°C ~ 60°C. Cold water was approximately 25°C. The air velocity was varied from 0.0656 m/s ~ 1.41 m/s. The heat transfer rate from the water flow to the air flow became large with an increase in the air velocity. The higher the water temperature was, the larger the heat transfer rate was. When the total heat flux from water to the air flow is divided into two terms; the evaporation term and the forced flow convection term, the evaporation term dominate main part and that is about 90 ~ 80 % of the total heat flux. The measured values of the evaporation term and the forced flow convection term were larger than the predicted because of the effect of the diffusion of evaporated vapor. The correlation to predict the heat transfer from the hot water flow to the cold air flow with the evaporation was developed by modifying the laminar flow mass transfer correlation and the laminar forced convection heat transfer correlation. Good results were obtained.
収録刊行物
-
- 混相流
-
混相流 26 (5), 523-530, 2013
日本混相流学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390001204437690496
-
- NII論文ID
- 10031163298
-
- NII書誌ID
- AN10088286
-
- ISSN
- 18815790
- 09142843
-
- NDL書誌ID
- 024396263
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- NDLサーチ
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可