書誌事項
- タイトル別名
-
- A Study of Availability of Paraffin Wax for Valve in Microfluidic Channel
- パラフィン ノ マイクロバルブ ト シテ ノ テキヨウセイ ノ ケントウ
この論文をさがす
抄録
Availability of a novel micro-valve made of paraffin wax which is used in a “swallowable biosensor” is studied. The valve was composed of a plug made of paraffin wax which sealed a micro fluid channel and micro heater to melt the paraffin plug. Additionally, a collecting area of paraffin after melting was formed downstream of the paraffin valve to prevents the melted paraffin from influencing on another devices in the swallowable biosensor. Shape of the collecting area for the melted paraffin was optimized by simulation using finite element method (FEM). As the result of simulation, it is found that two sloped weir, which is staggered each other, collected the most melted paraffin. Fabrication of the paraffin valve and the weirs collecting for the melted was also carried out. As a result of collecting test of melted paraffin, it was observed that two sloped weir collected most melted paraffin, which is the same result as the simulation.
収録刊行物
-
- 電気学会論文誌E(センサ・マイクロマシン部門誌)
-
電気学会論文誌E(センサ・マイクロマシン部門誌) 133 (1), 1-9, 2013
一般社団法人 電気学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390001204461486208
-
- NII論文ID
- 130003362844
- 10031142490
-
- NII書誌ID
- AN1052634X
-
- ISSN
- 13475525
- 13418939
-
- NDL書誌ID
- 024233579
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可