Buckling strength of FRP plates with a reineforced cut-out under axial compression. Stress concentration and buckling of square plates with a cut-out having doubler type reinforcement.
Bibliographic Information
- Other Title
-
- 開孔部補強FRP板の軸圧縮座屈強度 ダブラ形補強部を施した有孔正方形板の応力集中と座屈
- カイコウブ ホキョウ FRPバン ノ ジク アッシュク ザクツキョウド ダブラ
Search this article
Abstract
Numerical analyses the Finite Element Method have been carried out on the buckling strength and stress concentration in cross-ply laminated FRP plates with a reinforced square or circular cut-out under axial compression. The cross-ply plates used carbon-fiber/epoxy (CFRP) and glass-fiber/epoxy (GFRP). As one of the succesful ways in order to recover the buckling strength of the plate with a cut-out, the plate around the cut-out is reinforced by thickning the annular area. The result for a FRP Plate is compared with that for an isotropic plate. For a FRP Plate, the higher the fiber reinforcement, the more effective of the recovery of the buckling value.
Journal
-
- TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A
-
TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A 53 (490), 1099-1103, 1987
The Japan Society of Mechanical Engineers
- Tweet
Details 詳細情報について
-
- CRID
- 1390001204477099520
-
- NII Article ID
- 110002377306
-
- NII Book ID
- AN0018742X
-
- ISSN
- 18848338
- 03875008
-
- NDL BIB ID
- 3125882
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed