Measurement of Man's Convective Heat Transfer Coefficient by Using a Thermal Manikin in the Middle Wind Velocity Region
-
- KUWABARA Kouhei
- Graduate School of Hokkaido University
-
- MOCHIDA Tohru
- Graduate School of Hokkaido University
-
- KONDO Motoo
- Yamatake Building Systems Co., Ltd.
-
- MATSNAGA Kazuhiko
- Isuzu Motors Ltd.
Bibliographic Information
- Other Title
-
- サーマルマネキンを用いた中風速域における人体対流熱伝達率の測定
- サーマルマネキン オ モチイタ チュウ フウソクイキ ニ オケル ジンタイ タイリュウ ネツ デンタツリツ ノ ソクテイ
Search this article
Abstract
Because wind velocity in the outdoor environment is generally higher than that indoors, it is necessary to find the equation of man's convective heat transfer coefficient which can be used for the outdoor environment. In order to see how the convective heat transfer coefficient differs in the clothed state from that in the nude state, experiments which changed clo value were carried out. In the present experiment the equation for man's convective heat transfer coefficient was proposed in the wind range from 0.7m/s to 4.7m/s. In addition, it was confirmed that clo unit changed by wind velocity and convective heat transfer coefficient was not changed by clothes.