Optimum Control of Waste Heat Boiler and On-Off Operation of Fluidized Bed Incinerator being Supplied with of Municipal Soild Wastes.

Bibliographic Information

Other Title
  • 都市ごみ流動層炉における間欠運転と廃熱ボイラの最適制御
  • トシ ゴミ リュウドウソウロ ニ オケル カンケツ ウンテン ト ハイネツ ボ

Search this article

Abstract

Experiments were conducted to improve the thermal efficiency of a waste heat boiler fitted to a commercial fluidized bed incinerator being supplied with municipal solid waste (MSW). As a result, it was found that the control method, which is a operation of stopping fluidization instantaneously for the purpose of preventing excess steam generation, is effective. Furthermore, the daily on-off operation of a fluidized bed incinerator, which is the operation of maintaining the operational steam pressure using the heat accumulation in sand without feeding MSW at night and performing maximum combustion in the daytime, was confirmed to be effective for producing excess electric power.